  Datasheet File OCR Text:
 File name: TFS374D.doc
version 1.2
08.10.2003
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedances *) for input: for output: 23 C 5 dBm 277 177 || -3.5 pF || -4.9 pF
Filter specification
TFS 374D
1/5
Characteristics
Remark:
The reference level for the relative attenuation a rel of TFS374D is the minimum of the pass band attenuation a min. This value is defined as the insertion loss ae . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a e. The given values for the relative attenuation a rel and the group delay ripple have to be reached at the frequencies given below, even if the centre frequency f c is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss (Reference level) Nominal frequency Centre frequency 3 dB bandwidth Relative attenuation fN ... fN fN 7 MHz ... fN fN fN fN fN fN fN - 100 - 33 - 22 + 16,5 + 22 + 43 MHz MHz MHz MHz MHz MHz ... ... ... ... ... ... fN fN fN fN fN fN ae
fN fC
typ. value
8,7 374,000 MHz 23 0,8 54 53 40 44 48 49 40 40 TCf **)
tolerance/limit
max. 10 dB
dB
374,000 MHz min. max. max. min. min. min. min. min. min. 17 1 3 45 40 30 30 35 40 MHz dB dB dB dB dB dB dB dB ns dB
BW arel 7 MHz 8,5 MHz MHz MHz MHz MHz MHz MHz MHz
MHz dB dB dB dB dB dB dB ns dB
33 22 16,5 + 22 + 43 + 100 7
Group delay ripple in fN Triple transit suppression
max. 100 min. 30
Operating temperature range Storage temperature range Temperature coefficient of frequency Input power level
- 10 C ... + 85 C - 40 C ... + 85 C ppm/K max. 10 dBm
-87 -
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated: Checked / approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS374D.doc
version 1.2
08.10.2003
VI TELEFILTER
Filter specification
TFS 374D
2/5
Construction and pin configuration
(All dimensions in mm)
7
5
5
1,78
7
374D R18
1
data code
Pin Pin Pin Pin Pin Pin Pin Pin
1 2 3 4 5 6 7 8
Input Input RF-Return/ Input2 Ground Ground Output Output RF-Return/ Output2 Ground Ground
3
1,2 Max.
3
2,54
1
Date code: Year + week N 2001 P 2002 R 2003 ....
50
Test circuit 1 ( unbalanced )
L1 L2
1
5
C1
SAW
2 6
C2
3,4,7,8
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS374D.doc
version 1.2
08.10.2003
VI TELEFILTER
Stability characteristics
Filter specification
TFS 374D
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N
2. Vibration:
3. Change of temperature:
4. Resistance to solder heat (reflow): 4;
reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm
Ta p e (all d im en sio n s in m m ) W : 12 0,3 Po : 4 0 ,1 Do : 1 ,5 + 0 ,1 E : 1 ,7 5 0,1 F : 5, 5 0,0 5 G (m in ) : 0, 75 P2 : 2 0,0 5 P1 : 8 0, 1 D 1 (m in ) : 1,5 Ao : 4, 3 0,1 Bo : 4, 3 0,1 CT : 9 ,5 0, 1
E M B O S SE D C A R R IE R TA P E
Do
Po
P2
E Ao F W
D1 CT Bo
G
P1
C O V E R TA P E
W2
Reel (all dimensions in mm): A W1 : : 330 12,4 + 2,0 18,4 50 13 + 0,5 / -0,2
A C N
W 2 (max) : N (min) : C :
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS374D.doc
version 1.2
08.10.2003
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 374D
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
File name: TFS374D.doc
version 1.2
08.10.2003
VI TELEFILTER
Filter specification
TFS 374D
5/5
History version
1.0 1.1 1.2
reason of changes
generate specification add terminating impedances
name
Chilla Chilla
date
17.07.2003 25.09.2003 08.10.2003
change temperature coefficient of frequency Chilla add comments for terminating impedances and temperature coefficient of frequency
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS374D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X